Leave Your Message
Products Categories
    Featured Products

    Transfer Window

    The transfer window is an air purification equipment used in conjunction with clean workshops. It is suitable for the transfer of medium and small goods between clean rooms or between clean rooms and non-clean rooms. By using the transfer window, the number of opening and closing doors of the clean room can be reduced and the contamination of the clean area can be reduced to a minimum. Products are widely used in air purification places such as microtechnology, electronics industry, biological laboratories, pharmaceutical factories, hospitals, and food processing industries.

      The transfer window is an auxiliary equipment for clean rooms. It is mainly used to transfer small items between clean areas and between clean areas and non-clean areas to reduce the number of times the clean room opens and reduce the pollution to the clean room. 

      Principle of transfer window

      The transfer window is a device installed at the entrance and exit of a clean room or between rooms with different cleanliness levels to block indoor and outdoor airflow when transferring goods to prevent contaminated air from entering cleaner areas and causing cross-contamination. When the air shower type transfer window is transferring materials, the top blows out high-speed, clean airflow to blow away dust particles on the surface of the goods.
      At this time, the doors on both sides can be opened or closed, and the clean air flow acts as an airlock to ensure that the air outside the clean room does not affect the cleanliness of the room.Sealing strips are installed on the inner sides of the doors on both sides of the transfer window to ensure the air tightness of the transfer window.
      Stainless steel ordinary transfer window classification
      1. Electronic interlocking transfer window
      2. Mechanical interlocking transfer window
      3.Self-cleaning transfer window

      Advantages of the transfer window

      The transfer window is made of stainless steel plate, which is flat and smooth. The work surface of the long-distance transfer window adopts an unpowered roller, making it easy and convenient to transfer items. The double doors are interlocked to effectively prevent cross-contamination. They are equipped with electronic or mechanical interlocking devices and are equipped with ultraviolet germicidal lamps.transfer window application
      1. The transfer window is a transfer channel for materials between different clean areas.
      2. The door of the delivery window is usually closed. When delivering materials, the deliverer rings the doorbell first, and then opens a door when the other party responds. After sending the materials in, the door is closed immediately, and the recipient opens another door. After taking out the materials, close the door. It is strictly prohibited to open both doors at the same time.
      3. The transfer window should be cleaned and disinfected regularly after the operation.Use delivery window management system
      1.1 Pass-through windows are managed according to the relative cleanliness associated with them.
      1.2 No materials or debris can be placed in the transfer window.
      1.3 The clean area operator is responsible for management.Usage: The principle of using the transfer window is: open the door on one side
      Since all transfer windows are equipped with interlocking devices, the doors of the transfer windows can only be opened and closed on one side. Open the door of the transfer window (if the door on the other side is not closed, it cannot be opened), put the materials to be transferred into the transfer window, close the door of the transfer window, and the operator on the other side opens the door and takes out the materials from the transfer window , close the door to the pass window.

      Hygiene management

      The transfer window should be managed according to the cleanliness of the connected clean area. For example, the transfer window connected between the coding room and the filling room should be managed according to the requirements of the filling room. After the shift, the operator in the clean area will be responsible for wiping all internal surfaces of the transfer window clean and turning on the ultraviolet sterilization lamp for 30 minutes.Precautions
      1. Since the transfer window is interlocked, when the door on one side cannot be opened smoothly, it is because the door on the other side is not closed properly. Do not force it to open, otherwise the interlocking device will be damaged.
      2. When the material is cleaned from low to high, the surface of the material should be cleaned well.
      3. When the interlocking device of the transfer window cannot work properly, it should be repaired in time, otherwise it cannot be used.
      4. Check the working condition of the UV lamp frequently and replace the UV lamp regularly.
      5. No materials or debris can be stored in the transfer window.