Introducing the SW-CJ-1FD Clean Workbench, a premium solution designed for various applications in biopharmaceuticals, chemical experiments, medical and health sectors, as well as electronic optics. As a top manufacturer and supplier in China, we pride ourselves on delivering high-quality equipment that ensures a sterile and dust-free working environment. This clean workbench is perfect for any facility looking to maintain strict cleanliness and safety standards. Trust our factory to provide you with the best clean workbench that meets your specific needs.

    Structure

    The purification workbench is composed of several major components such as a box, a fan, a high-efficiency filter, and an operating switch. The box body is made of cold plate, etc., the surface is spray-painted, and the work surface is made of stainless steel. The purification unit adopts a fan system with adjustable air volume. By adjusting the working status of the fan, the average wind speed in the clean working area can be maintained within the rated range, and the service life of the high-efficiency filter is effectively extended.

    Working Principle

    The air passes through the primary filter, is pressed into the static pressure box by the centrifugal fan, and is filtered by the high-efficiency filter before being blown out from the air outlet surface to form a clean air flow. The clean air flow flows through the area that needs to be purified at a uniform cross-sectional wind speed, and the air in this area is The dust is taken away, thus forming a highly clean working environment.

    Install and Use

    This workbench should be placed in a workroom with a relatively clean environment (preferably in a primary clean room with a level of 100,000 or 300,000). Plug in the power and turn it on according to the function shown on the control panel. Before starting up, the working area and outer casing of the purification table should be carefully cleaned to remove dust on the surface. Normal operation can be carried out ten minutes after starting up.

    Maintain

    1 According to the actual usage, remove the primary filter and clean it regularly. The cleaning cycle is generally 3-6 months. (If it is not cleaned for a long time, dust accumulation will affect the insufficient air intake and reduce the cleaning effect.)
    2 When the ideal cross-sectional wind speed still cannot be achieved after normal replacement or cleaning of the primary filter air filter, the working voltage of the fan should be adjusted to achieve the ideal uniform wind speed.
    3 Generally, after eighteen years of use, when the fan operating voltage is adjusted to the highest point and still cannot reach the ideal wind speed, it means that the high-efficiency filter has too much dust (the filter holes on the filter material have been basically blocked, so it must be updated in time), the general service life of high-efficiency air filters is eighteen months.
    4 When replacing the high-efficiency air filter, you should pay attention to whether the model, specifications and dimensions are correct (original manufacturer configuration), install it according to the arrow wind direction, and pay attention to the surrounding seal of the filter to ensure that there is absolutely no leakage.

    Frequently Asked Questions

    What are the main components of the purification workbench?
    The purification workbench is composed of several major components including a box (made of cold plate with a spray-painted surface), a fan system with adjustable air volume, a high-efficiency filter, and an operating switch. The work surface is made of stainless steel.
    How does the purification workbench filter and clean the air?
    Air passes through the primary filter and is pressed into the static pressure box by a centrifugal fan. It is then filtered by a high-efficiency filter before being blown out from the air outlet surface. This clean air flow moves at a uniform cross-sectional wind speed, taking away dust and forming a highly clean working environment.
    Where should the workbench be installed and how should it be prepared?
    It should be placed in a relatively clean environment, preferably a primary clean room with a level of 100,000 or 300,000. Before starting up, carefully clean the working area and outer casing to remove surface dust. Normal operation can begin ten minutes after starting up.
    How often should the primary filter be cleaned?
    The primary filter should be removed and cleaned regularly, with a typical cleaning cycle of 3-6 months. Neglecting to clean it for a long time will lead to dust accumulation, which restricts air intake and reduces the cleaning effect.
    When does the high-efficiency air filter need to be replaced?
    It must be replaced when the fan operating voltage is adjusted to the highest point and the ideal wind speed still cannot be reached. This indicates the filter material's holes are blocked. The general service life of high-efficiency air filters is eighteen months.
    What is important to check when replacing the high-efficiency air filter?
    You must ensure that the model, specifications, and dimensions match the original manufacturer configuration. Install it according to the arrow wind direction, and verify that the surrounding seal is completely secure to prevent any leakage.